Articles |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
RS-232 Control of the Yaesu FRG-9600Interface Unit: FIF-232C (converts 5V TTL to RS-232 polar) Standard Connections Used: TXD, RXD, GND Flow Control: None (for the equipment featured here) Type of RS-232 Command Set: Binary, 5-byte fixed length frames (1-byte opcode + 4bytes of data/parameters) Data Parameters: 4800 bps (fixed), 1 start, 8 data + 2 stop bits FRG-9600 InterfaceThe FRG-9600 supports only frequency and mode set commands (no s-meter read). The format of command data (sent left to right) is as follows:
Note: the mode command does not use parameters, instead the opcode value itself is used |
|||||||||||||||||||||||||||||||||||||||||||||||||||||
|
This document maintained by