Articles

News

inde


Contact Information
Articles
Links

RS-232 Control of the Yaesu FRG-9600

Interface Unit: FIF-232C (converts 5V TTL to RS-232 polar)

Standard Connections Used: TXD, RXD, GND

Flow Control: None (for the equipment featured here)

Type of RS-232 Command Set: Binary, 5-byte fixed length frames (1-byte opcode + 4bytes of data/parameters)

Data Parameters: 4800 bps (fixed), 1 start, 8 data + 2 stop bits

FRG-9600 Interface

The FRG-9600 supports only frequency and mode set commands (no s-meter read).

The format of command data (sent left to right) is as follows:

1

2

3

4

5

Opcode 1st Arg 2nd Arg 3rd Arg 4th Arg

 

Function Opcode
(hex)
Arg1 Arg2 Arg3 Arg4 Argument description
Set Operating
Frequency
0ah f1 f2 f3 f4 New operating frequency in BCD format
Example: To set 145.250MHz the values of
f1-f4 are:
f1 14h
f2 52h
f3 50h
f4 00h

(note: lsb of f4 (for 10's Hz) is ignored)

Mode op - - - - Select mode as follows:
op mode
10h LSB
11h USB
14h AM-N
15h AM-W
16h FM-N
17h FM-W

Note: the mode command does not use parameters, instead the opcode value itself is used

Basics | Kenwood | Icom | Yaesu | AOR | At a glance

This document maintained by simon.collings@cableinet.co.uk.
Material Copyright © 2000 Simon Collings