RS-232 Interface Requirements at a Glance

Receiver Interface Unit Standard Connections Flow Control Paramaters
Kenwood
models
IF-232
Note: an interface kit
may also be required
for some models (eg
Kenwood IF-10A for
TS-711/811, IF-10B
for TS-940S and IF-10C
for TS-140/680, IC-10
for TS-440s/R-5000-
Check the requirements
for your model before
attempting to use
RS-232)
TXD, RXD, CTS, RTS, GND Hardware 4800bps, 1 start, 8 data & 2 stop
Note: higher data rates are supported with
latest models
Icom
models
CT-17 TXD, RXD, GND None
Note: Carrier Sense
Multiple Access
with Collision
Detection (CSMA/CD)
1200 bps , 1 start, 8 data + 1 stop bit
Note: standard baud rate, but
can be increased with some radios
FRG-8800
FRG-9600
FRG-100
FIF-232C TXD, RXD, GND None 4800 bps, 1 start, 8 data + 2 stop bits
AR-2500 None TXD, RXD, GND
(RTS/CTS also
required with some
models)
Hardware 300, 1200 and 9600 baud with 8 bits, no parity and 1 stop bit
Baud rate detection is automatic and relies
on the computer sending a <CR> character
repeatedly - when initialised, 'rS 232'
appears on the receiver's display).
AR-2700 CU-8232
Note: The AOR manual
recommends a maximum
length of RS-232 cable of 2 meters
TXD, RXD, GND Software 2400, 4800 or 9600 baud; 2 stop bits; no parity
AR-3000
AR-3000A
None TXD. RXD, GND, RTS. CTS Hardware 4800 baud; 2 stop bits; no parity
AR-3030 None TXD, RXD, GND, RTS. CTS Hardware 4800 or 9600 baud; 2 stop bits; no parity
AR-5000 None TXD, RXD, RTS, CTS, GND Software 4800, 9600 or 19200 baud; 2 stop bits; no parity
AR-8000 CU-8232
Note: The AOR manual
recommends a maximum
length of RS-232 cable of 2 meters
TXD, RXD, GND Software 2400, 4800 or 9600 baud; 2 stop bits; no parity
SDU-5000 None TXD, RXD, GND, RTS, CTS Software
Note: the SDU-5000
manual advises that
a three-wire hook-up
can be obtained by
linking RTS and CTS
together (pins 7 & 8)
at the SDU-5000 end
of the cable(presumably
RTS/CTS connections
are advised for
compatibilty with
some non-PC RS-232 interfaces)
9600 baud; 2 stop bits; no parity
ARD-2 None TXD, RXD, GND, RTS, CTS Hardware 9600 baud; 1 stop bits; no parity

Basics | Kenwood | Icom | Yaesu | AOR | At a glance